Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object DB0SON-3. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dg1h* Eff1h* Temp*
1789946749 14.1 Volt 340 Pkt 10 Pkt 75 Pcnt 19 C
1789946748 14.1 Volt 340 Pkt 10 Pkt 75 Pcnt 19 C
1789946148 14.1 Volt 330 Pkt 0 Pkt 74 Pcnt 19 C
1789945548 14.1 Volt 320 Pkt 0 Pkt 73 Pcnt 19.5 C
1789944949 14.1 Volt 330 Pkt 0 Pkt 74 Pcnt 19.5 C
1789944948 14.1 Volt 330 Pkt 0 Pkt 74 Pcnt 19.5 C
1789944348 14.1 Volt 330 Pkt 0 Pkt 74 Pcnt 19.5 C
1789943748 14.03 Volt 330 Pkt 10 Pkt 75 Pcnt 19.5 C
1789943150 14.1 Volt 320 Pkt 0 Pkt 76 Pcnt 20 C
1789943148 14.1 Volt 320 Pkt 0 Pkt 76 Pcnt 20 C
1789942548 14.1 Volt 330 Pkt 0 Pkt 74 Pcnt 20 C
1789941948 14.1 Volt 320 Pkt 0 Pkt 76 Pcnt 20 C
1789941349 14.1 Volt 310 Pkt 0 Pkt 73 Pcnt 20 C
1789941348 14.1 Volt 310 Pkt 0 Pkt 73 Pcnt 20 C
1789940748 14.1 Volt 320 Pkt 0 Pkt 74 Pcnt 20.5 C
1789940148 14.1 Volt 320 Pkt 0 Pkt 72 Pcnt 20.5 C
1789939549 14.1 Volt 330 Pkt 0 Pkt 69 Pcnt 20.5 C
1789939548 14.1 Volt 330 Pkt 0 Pkt 69 Pcnt 20.5 C
1789938948 14.1 Volt 330 Pkt 0 Pkt 69 Pcnt 20.5 C
1789938348 14.1 Volt 320 Pkt 0 Pkt 67 Pcnt 21 C
1789937749 14.03 Volt 320 Pkt 0 Pkt 69 Pcnt 21 C
1789937748 14.03 Volt 320 Pkt 0 Pkt 69 Pcnt 21 C
1789937148 14.1 Volt 350 Pkt 20 Pkt 68 Pcnt 21.5 C
1789936548 14.03 Volt 340 Pkt 20 Pkt 67 Pcnt 21.5 C
1789935949 14.1 Volt 350 Pkt 30 Pkt 69 Pcnt 22 C
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -64

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)