Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object E79XZA-10. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Rx10m* Rx1h* Dg10m* DgR* Eff*
1757545344 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757545044 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757544744 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757544444 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757544144 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757543844 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757543544 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757543244 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757542944 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757542644 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757542344 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757542044 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757541744 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757541444 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757541144 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757540844 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757540544 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757540244 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757539944 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757539644 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757539344 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757539044 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757538744 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757538444 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
1757538144 0 Pkt 0 Pkt 0 Pkt 0 Pcnt 0 Pcnt
*Used Equation Coefficients:
Rx10m: 0, 1, 0
Rx1h: 0, 10, 0
Dg10m: 0, 1, 0
DgR: 0, 0.001, 0
Eff: 0, 1, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)