Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object DO7AD-10. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dg1h* Eff1h* Temp*
1753628916 12.83 Volt 440 Pkt 0 Pkt 73 Pcnt 24 DegC
1753628016 12.83 Volt 460 Pkt 0 Pkt 73 Pcnt 24 DegC
1753627116 12.83 Volt 410 Pkt 0 Pkt 73 Pcnt 24 DegC
1753626216 12.83 Volt 360 Pkt 0 Pkt 73 Pcnt 24 DegC
1753625316 12.83 Volt 280 Pkt 0 Pkt 73 Pcnt 24 DegC
1753624416 12.83 Volt 220 Pkt 0 Pkt 73 Pcnt 24 DegC
1753623516 12.83 Volt 190 Pkt 0 Pkt 73 Pcnt 24 DegC
1753622616 12.83 Volt 170 Pkt 0 Pkt 73 Pcnt 24 DegC
1753621716 12.83 Volt 150 Pkt 0 Pkt 73 Pcnt 24 DegC
1753620816 12.83 Volt 150 Pkt 0 Pkt 73 Pcnt 24 DegC
1753619916 12.83 Volt 140 Pkt 0 Pkt 73 Pcnt 24 DegC
1753619016 12.83 Volt 150 Pkt 0 Pkt 73 Pcnt 24 DegC
1753618116 12.83 Volt 160 Pkt 0 Pkt 73 Pcnt 24 DegC
1753617216 12.83 Volt 170 Pkt 0 Pkt 73 Pcnt 24 DegC
1753616316 12.83 Volt 180 Pkt 0 Pkt 73 Pcnt 24 DegC
1753614516 12.83 Volt 200 Pkt 0 Pkt 73 Pcnt 24 DegC
1753613617 12.83 Volt 190 Pkt 0 Pkt 73 Pcnt 24 DegC
1753612717 12.83 Volt 160 Pkt 0 Pkt 73 Pcnt 24 DegC
1753611817 12.83 Volt 160 Pkt 0 Pkt 73 Pcnt 24 DegC
1753610917 12.83 Volt 160 Pkt 0 Pkt 73 Pcnt 24 DegC
1753610017 12.83 Volt 160 Pkt 0 Pkt 73 Pcnt 24 DegC
1753609117 12.83 Volt 180 Pkt 0 Pkt 73 Pcnt 24 DegC
1753608217 12.83 Volt 220 Pkt 0 Pkt 73 Pcnt 24 DegC
1753607317 12.83 Volt 250 Pkt 0 Pkt 73 Pcnt 24 DegC
1753606417 12.83 Volt 270 Pkt 0 Pkt 73 Pcnt 24 DegC
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -64

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)