Time Vin* Rx1h* Dg1h* Eff1h* Temp*
1757539327 12.83 Volt 770 Pkt 0 Pkt 76 Pcnt 22 DegC
1757538427 12.83 Volt 810 Pkt 0 Pkt 76 Pcnt 22.5 DegC
1757537527 12.83 Volt 780 Pkt 0 Pkt 76 Pcnt 22.5 DegC
1757536627 12.83 Volt 750 Pkt 0 Pkt 76 Pcnt 22.5 DegC
1757535727 12.83 Volt 740 Pkt 0 Pkt 76 Pcnt 22.5 DegC
1757534827 12.83 Volt 680 Pkt 0 Pkt 76 Pcnt 22.5 DegC
1757533927 12.83 Volt 690 Pkt 0 Pkt 76 Pcnt 22.5 DegC
1757533027 12.83 Volt 680 Pkt 0 Pkt 76 Pcnt 22.5 DegC
1757532127 12.83 Volt 670 Pkt 0 Pkt 76 Pcnt 22.5 DegC
1757531227 12.83 Volt 670 Pkt 0 Pkt 76 Pcnt 23 DegC
1757530327 12.83 Volt 670 Pkt 0 Pkt 76 Pcnt 23 DegC
1757529427 12.83 Volt 610 Pkt 0 Pkt 76 Pcnt 23 DegC
1757528527 12.83 Volt 580 Pkt 0 Pkt 75 Pcnt 23 DegC
1757527627 12.83 Volt 540 Pkt 0 Pkt 75 Pcnt 23 DegC
1757526727 12.83 Volt 500 Pkt 0 Pkt 75 Pcnt 23 DegC
1757525827 12.83 Volt 490 Pkt 0 Pkt 75 Pcnt 23 DegC
1757524927 12.83 Volt 490 Pkt 0 Pkt 75 Pcnt 23 DegC
1757524027 12.83 Volt 440 Pkt 0 Pkt 75 Pcnt 23 DegC
1757523127 12.83 Volt 400 Pkt 0 Pkt 75 Pcnt 23 DegC
1757522227 12.83 Volt 360 Pkt 0 Pkt 75 Pcnt 23 DegC
1757521327 12.83 Volt 330 Pkt 0 Pkt 75 Pcnt 23 DegC
1757520427 12.83 Volt 310 Pkt 0 Pkt 75 Pcnt 22.5 DegC
1757519527 12.83 Volt 280 Pkt 0 Pkt 75 Pcnt 22.5 DegC
1757518627 12.83 Volt 230 Pkt 0 Pkt 75 Pcnt 22.5 DegC
1757517727 12.83 Volt 210 Pkt 0 Pkt 76 Pcnt 23 DegC
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -64

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)