Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object VK5RPL-1. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Temp* Battery* TX* Value4* Value5*
1772949061 26.5 Deg.C 13.8 Volts 11 PTT's 15 30
1772947282 26 Deg.C 13.8 Volts 9 PTT's 15 1
1772945460 26 Deg.C 13.8 Volts 12 PTT's 14 30
1772943681 25.5 Deg.C 13.8 Volts 16 PTT's 14 1
1772941862 25 Deg.C 13.8 Volts 18 PTT's 13 30
1772940080 24.5 Deg.C 13.8 Volts 24 PTT's 13 1
1772938264 24 Deg.C 13.8 Volts 14 PTT's 12 30
1772936485 24 Deg.C 13.8 Volts 12 PTT's 12 1
1772934663 23.5 Deg.C 13.8 Volts 11 PTT's 11 30
1772932882 23.5 Deg.C 13.8 Volts 10 PTT's 11 1
1772927463 23 Deg.C 13.8 Volts 12 PTT's 9 30
1772925684 23 Deg.C 13.8 Volts 24 PTT's 9 1
1772923864 23 Deg.C 13.8 Volts 16 PTT's 8 30
1772922081 23 Deg.C 13.8 Volts 21 PTT's 8 1
1772920268 23 Deg.C 13.8 Volts 15 PTT's 7 30
1772918481 23 Deg.C 13.8 Volts 14 PTT's 7 1
1772916661 23 Deg.C 13.8 Volts 17 PTT's 6 30
1772914882 23.5 Deg.C 13.8 Volts 11 PTT's 6 1
1772913064 23.5 Deg.C 13.8 Volts 12 PTT's 5 30
1772911284 23.5 Deg.C 13.8 Volts 16 PTT's 5 1
1772909461 23.5 Deg.C 13.8 Volts 9 PTT's 4 30
1772907685 24 Deg.C 13.8 Volts 7 PTT's 4 1
1772905863 24 Deg.C 13.8 Volts 11 PTT's 3 30
1772904080 24 Deg.C 13.8 Volts 9 PTT's 3 1
1772902261 24.5 Deg.C 13.8 Volts 7 PTT's 2 30
*Used Equation Coefficients:
Temp: 0, 0.5, 0
Battery: 0, 0.1, 0
TX: 0, 1, 0
Value4: 0, 1, 0
Value5: 0, 1, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)