Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object VK4RBT-1. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dg1h* Eff1h* Temp*
1761618191 14.14 Volt 340 Pkt 10 Pkt 88 Pcnt 0 DegC
1761617291 14.14 Volt 340 Pkt 10 Pkt 89 Pcnt 0 DegC
1761616390 14.14 Volt 330 Pkt 10 Pkt 86 Pcnt 0 DegC
1761615489 14.14 Volt 320 Pkt 10 Pkt 87 Pcnt 0 DegC
1761614588 14.14 Volt 330 Pkt 10 Pkt 90 Pcnt 0 DegC
1761613691 14.14 Volt 320 Pkt 10 Pkt 91 Pcnt 0 DegC
1761612786 14.14 Volt 320 Pkt 10 Pkt 91 Pcnt 0 DegC
1761611885 14.14 Volt 340 Pkt 10 Pkt 91 Pcnt 0 DegC
1761610984 14.14 Volt 320 Pkt 10 Pkt 91 Pcnt 0 DegC
1761610087 14.14 Volt 330 Pkt 10 Pkt 92 Pcnt 0 DegC
1761609183 14.14 Volt 320 Pkt 10 Pkt 95 Pcnt 0 DegC
1761608282 14.14 Volt 300 Pkt 10 Pkt 95 Pcnt 0 DegC
1761607381 14.14 Volt 310 Pkt 10 Pkt 95 Pcnt 0 DegC
1761606480 14.14 Volt 300 Pkt 10 Pkt 95 Pcnt 0 DegC
1761605587 14.14 Volt 300 Pkt 10 Pkt 95 Pcnt 0 DegC
1761604678 14.14 Volt 300 Pkt 10 Pkt 95 Pcnt 0 DegC
1761603777 14.14 Volt 290 Pkt 10 Pkt 95 Pcnt 0 DegC
1761602876 14.14 Volt 280 Pkt 10 Pkt 94 Pcnt 0 DegC
1761601976 14.14 Volt 280 Pkt 10 Pkt 95 Pcnt 0 DegC
1761601075 14.14 Volt 270 Pkt 10 Pkt 95 Pcnt 0 DegC
1761600174 14.14 Volt 270 Pkt 10 Pkt 95 Pcnt 0 DegC
1761599273 14.14 Volt 260 Pkt 10 Pkt 95 Pcnt 0 DegC
1761598372 14.14 Volt 270 Pkt 10 Pkt 94 Pcnt 0 DegC
1761597471 14.14 Volt 260 Pkt 10 Pkt 94 Pcnt 0 DegC
1761596570 14.14 Volt 270 Pkt 10 Pkt 95 Pcnt 0 DegC
*Used Equation Coefficients:
Vin: 0, 0.079, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -64

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)