Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object S56RAL-10. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* T (E)* Eff1h* T (M)*
1789937367 13.8 Volt 240 Pkt -2 °C 59 Pcnt 0 None
1789937366 13.8 Volt 240 Pkt -2 °C 59 Pcnt 0 None
1789937067 13.8 Volt 240 Pkt -2.5 °C 58 Pcnt 0 None
1789937066 13.8 Volt 240 Pkt -2.5 °C 58 Pcnt 0 None
1789936767 13.8 Volt 240 Pkt -3 °C 57 Pcnt 0 None
1789936766 13.8 Volt 240 Pkt -3 °C 57 Pcnt 0 None
1789936466 13.8 Volt 240 Pkt -3.5 °C 58 Pcnt 0 None
1789936167 13.8 Volt 240 Pkt -4 °C 58 Pcnt 0 None
1789936166 13.8 Volt 240 Pkt -4 °C 58 Pcnt 0 None
1789935867 13.8 Volt 250 Pkt -4.5 °C 59 Pcnt 0 None
1789935866 13.8 Volt 250 Pkt -4.5 °C 59 Pcnt 0 None
1789935566 13.8 Volt 240 Pkt -4.5 °C 57 Pcnt 0 None
1789935267 13.8 Volt 240 Pkt -5 °C 56 Pcnt 0 None
1789935266 13.8 Volt 240 Pkt -5 °C 56 Pcnt 0 None
1789934967 13.8 Volt 240 Pkt -4.5 °C 57 Pcnt 0 None
1789934966 13.8 Volt 240 Pkt -4.5 °C 57 Pcnt 0 None
1789934666 13.8 Volt 240 Pkt -4 °C 57 Pcnt 0 None
1789934367 13.8 Volt 240 Pkt -2.5 °C 56 Pcnt 0 None
1789934366 13.8 Volt 240 Pkt -2.5 °C 56 Pcnt 0 None
1789934081 13.8 Volt 240 Pkt -2 °C 57 Pcnt 0 None
1789933767 13.8 Volt 230 Pkt -2.5 °C 55 Pcnt 0 None
1789933766 13.8 Volt 230 Pkt -2.5 °C 55 Pcnt 0 None
1789933466 13.8 Volt 230 Pkt -3 °C 56 Pcnt 0 None
1789933167 13.8 Volt 230 Pkt -3.5 °C 55 Pcnt 0 None
1789933166 13.8 Volt 230 Pkt -3.5 °C 55 Pcnt 0 None
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
T (E): 0, 0.5, -64
Eff1h: 0, 1, 0
T (M): 0, 0.5, -64

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)