Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object DL6DCA-8. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 >>
Time Voltage* Celsius* Rel_Hum* Atm_Press* Value5*
1780763542 3.97 VDC 36.9 C 25.55 % 1014.75 hPa 0
1780747689 4.02 VDC 40.4 C 19.9 % 1015.13 hPa 0
1780747486 4.01 VDC 40.9 C 19.83 % 1015.5 hPa 0
1780746969 3.96 VDC 41.8 C 19.3 % 1018.38 hPa 0
1780745672 3.69 VDC 40.8 C 23.34 % 1016 hPa 0
1780740387 3.51 VDC 43.7 C 24.73 % 1016.63 hPa 0
1780737556 3.83 VDC 37.7 C 27.41 % 1015.88 hPa 0
1780737392 3.81 VDC 36.8 C 28.72 % 1016.63 hPa 0
1780675717 3.69 VDC 29 C 35.26 % 1013.38 hPa 0
1780614790 3.42 VDC 17.6 C 44.53 % 1002.75 hPa 0
1780605760 3.57 VDC 19.5 C 43.83 % 1001.38 hPa 0
1780596730 3.67 VDC 24 C 41.12 % 1000.63 hPa 0
1780576770 3.79 VDC 30 C 33.33 % 1001.38 hPa 0
1780574505 4.1 VDC 37.5 C 23.76 % 1001 hPa 0
1780572004 4.06 VDC 38.5 C 23.36 % 1000.88 hPa 0
1780562581 3.8 VDC 35 C 30.68 % 1001.63 hPa 0
1780528560 3.38 VDC 20.2 C 38.87 % 1003.38 hPa 0
1780519530 3.56 VDC 22.4 C 37.87 % 1004.13 hPa 0
1780433023 3.42 VDC 26.7 C 34.05 % 1003.63 hPa 0
1780419877 3.97 VDC 41.1 C 17.56 % 1005 hPa 0
1780419686 3.94 VDC 41.4 C 18.42 % 1004.38 hPa 0
1780419461 3.89 VDC 41.8 C 18.76 % 1005.5 hPa 0
1780419245 3.84 VDC 42.1 C 18.98 % 1008.75 hPa 0
1780418967 3.79 VDC 42.3 C 16.95 % 1004 hPa 0
1780418790 3.76 VDC 42.5 C 16.98 % 1003.38 hPa 0
*Used Equation Coefficients:
Voltage: 0, 0.01, 0
Celsius: 0, 0.1, -50
Rel_Hum: 0, 0.01, 0
Atm_Press: 0, 0.125, 0
Value5: 0, 1, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)