Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object YO8CLN-2. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 >>
Time Vin* T* Eff1h* RX* TX*
1761492299 1190 V 1300 C 28 Pcnt 0 Pkt 0 Pkt
1761489292 1240 V 1310 C 33 Pcnt 0 Pkt 0 Pkt
1761486288 1280 V 1310 C 18 Pcnt 0 Pkt 0 Pkt
1761483286 1260 V 1310 C 17 Pcnt 0 Pkt 0 Pkt
1761480285 1290 V 1310 C 33 Pcnt 0 Pkt 0 Pkt
1761477278 1340 V 1310 C 29 Pcnt 0 Pkt 0 Pkt
1761474276 1350 V 1300 C 21 Pcnt 0 Pkt 0 Pkt
1761468274 1360 V 1280 C 22 Pcnt 0 Pkt 0 Pkt
1761465269 1440 V 1280 C 36 Pcnt 0 Pkt 0 Pkt
1761462265 1420 V 1260 C 19 Pcnt 0 Pkt 0 Pkt
1761409562 1130 V 1250 C 21 Pcnt 0 Pkt 0 Pkt
1761406558 1230 V 1260 C 10 Pcnt 0 Pkt 0 Pkt
1761400553 1270 V 1270 C 22 Pcnt 0 Pkt 0 Pkt
1761397550 1280 V 1280 C 38 Pcnt 0 Pkt 0 Pkt
1761385540 1330 V 1270 C 25 Pcnt 0 Pkt 0 Pkt
1761382536 1430 V 1270 C 17 Pcnt 0 Pkt 0 Pkt
1761379537 1430 V 1260 C 26 Pcnt 0 Pkt 0 Pkt
1761376532 1420 V 1250 C 25 Pcnt 0 Pkt 0 Pkt
1761373527 1420 V 1240 C 20 Pcnt 0 Pkt 0 Pkt
1761310597 1310 V 1340 C 100 Pcnt 0 Pkt 0 Pkt
1761307028 1080 V 1360 C 47 Pcnt 0 Pkt 0 Pkt
1761304026 1110 V 1360 C 51 Pcnt 0 Pkt 0 Pkt
1761301026 1160 V 1370 C 33 Pcnt 0 Pkt 0 Pkt
1761298019 1280 V 1370 C 27 Pcnt 0 Pkt 0 Pkt
1761295021 1140 V 1370 C 20 Pcnt 0 Pkt 0 Pkt
*Used Equation Coefficients:
Vin: 0, 10, 0
T: 0, 10, 0
Eff1h: 0, 1, 0
RX: 0, 0, 0
TX: 0, 0, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)