Time Temp* Hum* Pres* Wind* Rain*
1787566673 30 degC 78 % 1008 hPa 11 kmh 0 mm
1787564796 30 degC 76 % 1008 hPa 11 kmh 0 mm
1787562922 30.5 degC 74 % 1008 hPa 10 kmh 0 mm
1787561056 31 degC 72 % 1008 hPa 11 kmh 0 mm
1787559193 31 degC 70 % 1008 hPa 11 kmh 0 mm
1787555469 31.5 degC 65 % 1009 hPa 7 kmh 0.1 mm
1787553607 31 degC 67 % 1009 hPa 9 kmh 0 mm
1787551741 31.5 degC 64 % 1010 hPa 7 kmh 0.1 mm
1787549871 32 degC 62 % 1010 hPa 5 kmh 0.1 mm
1787547990 32 degC 61 % 1011 hPa 2 kmh 0 mm
1787546127 31.5 degC 64 % 1011 hPa 1 kmh 0 mm
1787544268 31 degC 67 % 1011 hPa 1 kmh 0 mm
1787542409 31 degC 69 % 1011 hPa 1 kmh 0 mm
1787540550 30.5 degC 71 % 1012 hPa 3 kmh 0 mm
1787538691 30 degC 75 % 1012 hPa 4 kmh 0 mm
1787536959 29 degC 80 % 1012 hPa 5 kmh 0 mm
1787534961 27.5 degC 88 % 1012 hPa 5 kmh 0 mm
1787533092 26.5 degC 92 % 1011 hPa 5 kmh 0 mm
1787531235 26 degC 94 % 1011 hPa 6 kmh 0 mm
1787529378 25.5 degC 97 % 1011 hPa 5 kmh 0 mm
1787527522 25 degC 98 % 1010 hPa 6 kmh 0 mm
1787525665 25 degC 98 % 1010 hPa 6 kmh 0 mm
1787523794 25 degC 98 % 1010 hPa 5 kmh 0 mm
1787521926 25 degC 98 % 1010 hPa 5 kmh 0 mm
1787520048 25 degC 98 % 1010 hPa 5 kmh 0 mm
*Used Equation Coefficients:
Temp: 0, 0.5, -20
Hum: 0, 1, 0
Pres: 0, 1, 800
Wind: 0, 1, 0
Rain: 0, 0.1, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)