Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object OZ0LLH. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dg1h* Eff1h* A5*
1765598249 12.6 Volt 160 Pkt 50 Pkt 68 Pcnt 0 None
1765597651 12.6 Volt 140 Pkt 50 Pkt 65 Pcnt 0 None
1765597649 12.6 Volt 140 Pkt 50 Pkt 65 Pcnt 0 None
1765597050 12.6 Volt 150 Pkt 50 Pkt 67 Pcnt 0 None
1765596449 12.6 Volt 150 Pkt 50 Pkt 71 Pcnt 0 None
1765595850 12.68 Volt 140 Pkt 50 Pkt 70 Pcnt 0 None
1765595250 12.6 Volt 150 Pkt 50 Pkt 72 Pcnt 0 None
1765594650 12.68 Volt 140 Pkt 50 Pkt 72 Pcnt 0 None
1765594050 12.6 Volt 140 Pkt 50 Pkt 76 Pcnt 0 None
1765594049 12.6 Volt 140 Pkt 50 Pkt 76 Pcnt 0 None
1765593450 12.68 Volt 140 Pkt 50 Pkt 73 Pcnt 0 None
1765592850 12.68 Volt 140 Pkt 50 Pkt 72 Pcnt 0 None
1765592250 12.68 Volt 150 Pkt 50 Pkt 71 Pcnt 0 None
1765591650 12.68 Volt 150 Pkt 50 Pkt 69 Pcnt 0 None
1765591050 12.68 Volt 150 Pkt 50 Pkt 69 Pcnt 0 None
1765590450 12.6 Volt 160 Pkt 50 Pkt 70 Pcnt 0 None
1765590449 12.6 Volt 160 Pkt 50 Pkt 70 Pcnt 0 None
1765589850 12.68 Volt 160 Pkt 50 Pkt 68 Pcnt 0 None
1765589250 12.68 Volt 160 Pkt 50 Pkt 65 Pcnt 0 None
1765588650 12.68 Volt 140 Pkt 40 Pkt 62 Pcnt 0 None
1765588050 12.68 Volt 130 Pkt 50 Pkt 60 Pcnt 0 None
1765587450 12.68 Volt 150 Pkt 50 Pkt 64 Pcnt 0 None
1765586850 12.68 Volt 140 Pkt 50 Pkt 62 Pcnt 0 None
1765586849 12.68 Volt 140 Pkt 50 Pkt 62 Pcnt 0 None
1765586250 12.68 Volt 140 Pkt 50 Pkt 64 Pcnt 0 None
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
A5: 0, 0, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)