Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object S55YLI-11. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dg1h* Eff1h* Temp*
1784669266 12.3 Volt 1220 Pkt 300 Pkt 73 Pcnt 0 C
1784669261 12.3 Volt 1220 Pkt 300 Pkt 73 Pcnt 0 C
1784668961 12.3 Volt 1240 Pkt 300 Pkt 74 Pcnt 0 C
1784668663 12.23 Volt 1240 Pkt 310 Pkt 73 Pcnt 0 C
1784668661 12.23 Volt 1240 Pkt 310 Pkt 73 Pcnt 0 C
1784668361 12.3 Volt 1240 Pkt 310 Pkt 73 Pcnt 0 C
1784668064 12.3 Volt 1200 Pkt 310 Pkt 74 Pcnt 0 C
1784668061 12.3 Volt 1200 Pkt 310 Pkt 74 Pcnt 0 C
1784667761 12.23 Volt 1220 Pkt 310 Pkt 73 Pcnt 0 C
1784667462 12.3 Volt 1200 Pkt 310 Pkt 73 Pcnt 0 C
1784667461 12.3 Volt 1200 Pkt 310 Pkt 73 Pcnt 0 C
1784667161 12.3 Volt 1200 Pkt 300 Pkt 73 Pcnt 0 C
1784666862 12.3 Volt 1210 Pkt 310 Pkt 74 Pcnt 0 C
1784666861 12.3 Volt 1210 Pkt 310 Pkt 74 Pcnt 0 C
1784666561 12.3 Volt 1230 Pkt 310 Pkt 74 Pcnt 0 C
1784666264 12.3 Volt 1230 Pkt 320 Pkt 74 Pcnt 0 C
1784666261 12.3 Volt 1230 Pkt 320 Pkt 74 Pcnt 0 C
1784665961 12.3 Volt 1230 Pkt 320 Pkt 74 Pcnt 0 C
1784665662 12.3 Volt 1230 Pkt 320 Pkt 75 Pcnt 0 C
1784665661 12.3 Volt 1230 Pkt 320 Pkt 75 Pcnt 0 C
1784665361 12.3 Volt 1230 Pkt 320 Pkt 75 Pcnt 0 C
1784665062 12.08 Volt 1220 Pkt 310 Pkt 76 Pcnt 0 C
1784665061 12.08 Volt 1220 Pkt 310 Pkt 76 Pcnt 0 C
1784664761 12.3 Volt 1250 Pkt 330 Pkt 76 Pcnt 0 C
1784664463 12.3 Volt 1240 Pkt 330 Pkt 76 Pcnt 0 C
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -64

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)