Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object KNAPPA. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Battery* Watts* Array-East* Array-West* Charging*
1773207392 13.1 Volts 0 W 0 V 0.14 V 0 A
1773206762 13.1 Volts 0 W 0.01 V 0.11 V 0 A
1773206132 13.1 Volts 0 W 0 V 0.12 V 0 A
1773205502 13.1 Volts 0 W 0.05 V 0 V 0 A
1773204872 13.1 Volts 0 W 0 V 0.07 V 0 A
1773203613 13.1 Volts 0 W 0.03 V 0 V 0 A
1773202982 13.1 Volts 0 W 0.01 V 0.1 V 0 A
1773202352 13.1 Volts 0 W 0 V 0.07 V 0 A
1773201723 13.11 Volts 0 W 0.04 V 0.01 V 0 A
1773201092 13.11 Volts 0 W 0.03 V 0.1 V 0 A
1773200462 13.11 Volts 0 W 0.02 V 0.17 V 0 A
1773199832 13.12 Volts 0 W 0.03 V 0 V 0 A
1773199203 13.12 Volts 0 W 0.03 V 0.1 V 0 A
1773198571 13.12 Volts 0 W 0.03 V 0.09 V 0 A
1773197942 13.12 Volts 0 W 0.09 V 0.13 V 0 A
1773197316 13.11 Volts 0 W 0.53 V 0.99 V 0 A
1773196682 13.11 Volts 0 W 4.66 V 10.13 V 0 A
1773196052 13.14 Volts 0 W 14.12 V 13.93 V 0.02 A
1773195422 13.15 Volts 0 W 14.13 V 13.97 V 0.03 A
1773194792 13.15 Volts 1 W 14.2 V 13.99 V 0.07 A
1773194162 13.15 Volts 4 W 14.23 V 14.05 V 0.28 A
1773193532 13.17 Volts 6 W 14.27 V 14.11 V 0.42 A
1773192902 13.19 Volts 8 W 14.32 V 14.14 V 0.6 A
1773192272 13.26 Volts 45 W 51.26 V 51.23 V 3.4 A
1773191642 13.24 Volts 53 W 51.55 V 52.42 V 4.02 A
*Used Equation Coefficients:
Battery: 0, 1, 0
Watts: 0, 1, 0
Array-East: 0, 1, 0
Array-West: 0, 1, 0
Charging: 0, 1, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)