Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object ED4ZAJ-3. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dg1h* Eff1h* I2*
1772614172 13.95 Volt 120 Pkt 90 Pkt 65 Pcnt 780.8 mA
1772610546 13.95 Volt 110 Pkt 70 Pkt 75 Pcnt 780.8 mA
1772606943 13.95 Volt 100 Pkt 70 Pkt 75 Pcnt 790.56 mA
1772603339 13.95 Volt 80 Pkt 60 Pkt 74 Pcnt 790.56 mA
1772599736 13.95 Volt 70 Pkt 50 Pkt 76 Pcnt 790.56 mA
1772596132 13.95 Volt 90 Pkt 50 Pkt 86 Pcnt 790.56 mA
1772592529 13.95 Volt 70 Pkt 50 Pkt 86 Pcnt 790.56 mA
1772588925 13.95 Volt 80 Pkt 50 Pkt 82 Pcnt 790.56 mA
1772585322 13.95 Volt 80 Pkt 50 Pkt 83 Pcnt 790.56 mA
1772581718 13.95 Volt 80 Pkt 50 Pkt 74 Pcnt 790.56 mA
1772578115 13.95 Volt 70 Pkt 50 Pkt 82 Pcnt 790.56 mA
1772574511 13.95 Volt 90 Pkt 60 Pkt 86 Pcnt 790.56 mA
1772570908 13.95 Volt 90 Pkt 60 Pkt 80 Pcnt 790.56 mA
1772567305 13.95 Volt 200 Pkt 100 Pkt 88 Pcnt 790.56 mA
1772563706 13.95 Volt 280 Pkt 140 Pkt 91 Pcnt 780.8 mA
1772560100 13.95 Volt 130 Pkt 70 Pkt 84 Pcnt 780.8 mA
1772556494 13.95 Volt 130 Pkt 90 Pkt 84 Pcnt 780.8 mA
1772552891 13.95 Volt 160 Pkt 100 Pkt 85 Pcnt 780.8 mA
1772549287 13.95 Volt 100 Pkt 70 Pkt 76 Pcnt 780.8 mA
1772545684 13.95 Volt 130 Pkt 80 Pkt 73 Pcnt 780.8 mA
1772538477 13.95 Volt 110 Pkt 70 Pkt 75 Pcnt 780.8 mA
1772534873 13.95 Volt 90 Pkt 60 Pkt 72 Pcnt 780.8 mA
1772531270 13.95 Volt 110 Pkt 70 Pkt 75 Pcnt 780.8 mA
1772524063 13.88 Volt 180 Pkt 100 Pkt 86 Pcnt 780.8 mA
1772520459 13.95 Volt 90 Pkt 50 Pkt 86 Pcnt 780.8 mA
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
I2: 0, 9.76, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)