Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object VK5RBV-1. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dig1h* Eff1h* Temp*
1776676822 13.76 Volt 22 Pkt 2 Pkt 87 Pcnt 0 C
1776673219 13.76 Volt 28 Pkt 2 Pkt 90 Pcnt 0 C
1776669615 13.76 Volt 27 Pkt 3 Pkt 88 Pcnt 0 C
1776666012 13.76 Volt 25 Pkt 2 Pkt 89 Pcnt 0 C
1776662409 13.76 Volt 24 Pkt 2 Pkt 91 Pcnt 0 C
1776658805 13.76 Volt 23 Pkt 2 Pkt 93 Pcnt 0 C
1776655202 13.76 Volt 23 Pkt 2 Pkt 81 Pcnt 0 C
1776651598 13.76 Volt 20 Pkt 2 Pkt 84 Pcnt 0 C
1776647995 13.76 Volt 21 Pkt 2 Pkt 89 Pcnt 0 C
1776644391 13.76 Volt 24 Pkt 2 Pkt 86 Pcnt 0 C
1776640788 13.76 Volt 24 Pkt 3 Pkt 87 Pcnt 0 C
1776637184 13.76 Volt 22 Pkt 2 Pkt 91 Pcnt 0 C
1776633581 13.76 Volt 23 Pkt 3 Pkt 84 Pcnt 0 C
1776629977 13.25 Volt 21 Pkt 3 Pkt 86 Pcnt 0 C
1776626374 13.76 Volt 19 Pkt 1 Pkt 88 Pcnt 0 C
1776622770 13.76 Volt 16 Pkt 2 Pkt 85 Pcnt 0 C
1776619167 13.76 Volt 16 Pkt 3 Pkt 92 Pcnt 0 C
1776615563 13.76 Volt 18 Pkt 3 Pkt 93 Pcnt 0 C
1776611960 13.76 Volt 18 Pkt 4 Pkt 90 Pcnt 0 C
1776608356 13.76 Volt 18 Pkt 4 Pkt 89 Pcnt 0 C
1776604753 13.76 Volt 20 Pkt 4 Pkt 86 Pcnt 0 C
1776601151 13.76 Volt 19 Pkt 4 Pkt 85 Pcnt 0 C
1776597546 13.76 Volt 17 Pkt 4 Pkt 88 Pcnt 0 C
1776593942 13.84 Volt 13 Pkt 2 Pkt 88 Pcnt 0 C
1776590339 13.76 Volt 15 Pkt 2 Pkt 88 Pcnt 0 C
*Used Equation Coefficients:
Vin: 0, 0.074, 0
Rx1h: 0, 1, 0
Dig1h: 0, 1, 0
Eff1h: 0, 1, 0
Temp: 0, 0, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)