Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object VK5RBV-1. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dig1h* Eff1h* Temp*
1772716597 13.76 Volt 39 Pkt 4 Pkt 86 Pcnt 0 C
1772712993 13.76 Volt 29 Pkt 3 Pkt 85 Pcnt 0 C
1772709390 13.76 Volt 26 Pkt 2 Pkt 85 Pcnt 0 C
1772705786 13.76 Volt 29 Pkt 2 Pkt 83 Pcnt 0 C
1772702196 13.76 Volt 23 Pkt 4 Pkt 91 Pcnt 0 C
1772698579 13.76 Volt 27 Pkt 3 Pkt 86 Pcnt 0 C
1772694976 13.76 Volt 22 Pkt 1 Pkt 88 Pcnt 0 C
1772691372 13.47 Volt 26 Pkt 2 Pkt 93 Pcnt 0 C
1772687769 13.76 Volt 17 Pkt 2 Pkt 92 Pcnt 0 C
1772684165 13.76 Volt 18 Pkt 2 Pkt 90 Pcnt 0 C
1772680562 13.76 Volt 23 Pkt 2 Pkt 89 Pcnt 0 C
1772676958 13.76 Volt 35 Pkt 2 Pkt 88 Pcnt 0 C
1772673355 13.76 Volt 43 Pkt 3 Pkt 88 Pcnt 0 C
1772669751 13.76 Volt 67 Pkt 3 Pkt 85 Pcnt 0 C
1772662544 13.76 Volt 79 Pkt 4 Pkt 84 Pcnt 0 C
1772658941 13.69 Volt 74 Pkt 7 Pkt 80 Pcnt 0 C
1772655337 13.69 Volt 60 Pkt 5 Pkt 81 Pcnt 0 C
1772651734 13.76 Volt 53 Pkt 5 Pkt 75 Pcnt 0 C
1772648130 13.76 Volt 54 Pkt 5 Pkt 82 Pcnt 0 C
1772644527 13.76 Volt 44 Pkt 3 Pkt 80 Pcnt 0 C
1772640926 13.76 Volt 39 Pkt 4 Pkt 71 Pcnt 0 C
1772637320 13.76 Volt 36 Pkt 4 Pkt 74 Pcnt 0 C
1772633717 13.76 Volt 39 Pkt 4 Pkt 79 Pcnt 0 C
1772630113 13.76 Volt 34 Pkt 4 Pkt 86 Pcnt 0 C
1772622906 13.76 Volt 27 Pkt 3 Pkt 77 Pcnt 0 C
*Used Equation Coefficients:
Vin: 0, 0.074, 0
Rx1h: 0, 1, 0
Dig1h: 0, 1, 0
Eff1h: 0, 1, 0
Temp: 0, 0, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)