Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object IR5AO. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dg1h* Eff1h* Eff*
1776675100 12.17 Volt 770 Pkt 150 Pkt 93 Pcnt 93 Pcnt
1776675099 12.17 Volt 770 Pkt 150 Pkt 93 Pcnt 93 Pcnt
1776674499 12.17 Volt 810 Pkt 170 Pkt 93 Pcnt 93 Pcnt
1776673899 12.17 Volt 820 Pkt 170 Pkt 94 Pcnt 93 Pcnt
1776673299 12.17 Volt 820 Pkt 170 Pkt 95 Pcnt 93 Pcnt
1776672699 12.17 Volt 780 Pkt 170 Pkt 95 Pcnt 93 Pcnt
1776672099 12.17 Volt 770 Pkt 180 Pkt 94 Pcnt 93 Pcnt
1776671500 12.17 Volt 720 Pkt 160 Pkt 93 Pcnt 93 Pcnt
1776671499 12.17 Volt 720 Pkt 160 Pkt 93 Pcnt 93 Pcnt
1776670901 12.17 Volt 670 Pkt 150 Pkt 92 Pcnt 92 Pcnt
1776670900 12.17 Volt 670 Pkt 150 Pkt 92 Pcnt 92 Pcnt
1776670300 12.17 Volt 640 Pkt 150 Pkt 93 Pcnt 92 Pcnt
1776670299 12.17 Volt 640 Pkt 150 Pkt 93 Pcnt 92 Pcnt
1776669700 12.17 Volt 610 Pkt 130 Pkt 93 Pcnt 92 Pcnt
1776669699 12.17 Volt 610 Pkt 130 Pkt 93 Pcnt 92 Pcnt
1776669100 12.17 Volt 620 Pkt 120 Pkt 92 Pcnt 92 Pcnt
1776669099 12.17 Volt 620 Pkt 120 Pkt 92 Pcnt 92 Pcnt
1776668501 12.17 Volt 600 Pkt 110 Pkt 93 Pcnt 92 Pcnt
1776668499 12.17 Volt 600 Pkt 110 Pkt 93 Pcnt 92 Pcnt
1776667900 12.17 Volt 620 Pkt 110 Pkt 92 Pcnt 92 Pcnt
1776667899 12.17 Volt 620 Pkt 110 Pkt 92 Pcnt 92 Pcnt
1776667300 12.17 Volt 660 Pkt 120 Pkt 92 Pcnt 92 Pcnt
1776667299 12.17 Volt 660 Pkt 120 Pkt 92 Pcnt 92 Pcnt
1776666700 12.17 Volt 700 Pkt 120 Pkt 92 Pcnt 92 Pcnt
1776666700 12.17 Volt 700 Pkt 120 Pkt 92 Pcnt 92 Pcnt
*Used Equation Coefficients:
Vin: 0, 0.079, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Eff: 0, 1, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)