This is the latest recevied telemetry packets stored in our database for station/object IR1ZXE-11. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dg1h* Eff1h* A5*
1761497494 12.38 Volt 250 Pkt 50 Pkt 69 Pcnt 0 None
1761495692 12.38 Volt 200 Pkt 40 Pkt 67 Pcnt 0 None
1761493890 12.38 Volt 180 Pkt 40 Pkt 65 Pcnt 0 None
1761492088 12.38 Volt 150 Pkt 30 Pkt 60 Pcnt 0 None
1761490287 12.38 Volt 140 Pkt 20 Pkt 57 Pcnt 0 None
1761488485 12.38 Volt 140 Pkt 20 Pkt 56 Pcnt 0 None
1761486683 12.38 Volt 150 Pkt 20 Pkt 59 Pcnt 0 None
1761483080 12.38 Volt 180 Pkt 30 Pkt 70 Pcnt 0 None
1761481278 12.38 Volt 170 Pkt 30 Pkt 72 Pcnt 0 None
1761475873 12.38 Volt 90 Pkt 20 Pkt 64 Pcnt 0 None
1761474071 12.38 Volt 90 Pkt 20 Pkt 64 Pcnt 0 None
1761472269 12.38 Volt 140 Pkt 30 Pkt 64 Pcnt 0 None
1761468666 12.38 Volt 160 Pkt 30 Pkt 70 Pcnt 0 None
1761466864 12.38 Volt 200 Pkt 40 Pkt 72 Pcnt 0 None
1761463262 12.38 Volt 170 Pkt 40 Pkt 74 Pcnt 0 None
1761461459 12.38 Volt 170 Pkt 40 Pkt 69 Pcnt 0 None
1761459657 12.38 Volt 170 Pkt 40 Pkt 65 Pcnt 0 None
1761457855 12.38 Volt 190 Pkt 50 Pkt 67 Pcnt 0 None
1761456054 12.38 Volt 190 Pkt 50 Pkt 70 Pcnt 0 None
1761454252 12.38 Volt 200 Pkt 40 Pkt 75 Pcnt 0 None
1761452450 12.38 Volt 190 Pkt 40 Pkt 75 Pcnt 0 None
1761448847 12.38 Volt 200 Pkt 40 Pkt 76 Pcnt 0 None
1761447045 12.38 Volt 200 Pkt 40 Pkt 74 Pcnt 0 None
1761445243 12.38 Volt 200 Pkt 40 Pkt 74 Pcnt 0 None
1761441640 12.38 Volt 170 Pkt 30 Pkt 73 Pcnt 0 None
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
A5: 0, 0, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)