Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object OE8XDR-10. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dg1h* Eff1h* Temp*
1780544846 14.33 Volt 310 Pkt 20 Pkt 39 Pcnt 18.5 C
1780544546 14.33 Volt 310 Pkt 20 Pkt 40 Pcnt 18.5 C
1780544246 14.33 Volt 310 Pkt 20 Pkt 39 Pcnt 18.5 C
1780543946 14.33 Volt 300 Pkt 20 Pkt 38 Pcnt 18.5 C
1780543646 14.33 Volt 300 Pkt 20 Pkt 39 Pcnt 18.5 C
1780543346 14.33 Volt 300 Pkt 20 Pkt 37 Pcnt 18 C
1780543046 14.33 Volt 300 Pkt 20 Pkt 38 Pcnt 18.5 C
1780542746 14.33 Volt 300 Pkt 10 Pkt 38 Pcnt 18.5 C
1780542446 14.33 Volt 290 Pkt 10 Pkt 37 Pcnt 18.5 C
1780542146 14.33 Volt 270 Pkt 10 Pkt 37 Pcnt 18.5 C
1780541846 14.33 Volt 260 Pkt 10 Pkt 36 Pcnt 18.5 C
1780541547 14.33 Volt 270 Pkt 10 Pkt 36 Pcnt 18.5 C
1780541546 14.33 Volt 270 Pkt 10 Pkt 36 Pcnt 18.5 C
1780541246 14.25 Volt 270 Pkt 20 Pkt 36 Pcnt 18.5 C
1780540946 14.33 Volt 270 Pkt 10 Pkt 37 Pcnt 18 C
1780540646 14.18 Volt 270 Pkt 10 Pkt 37 Pcnt 18 C
1780540346 14.33 Volt 260 Pkt 10 Pkt 37 Pcnt 18 C
1780540046 14.33 Volt 260 Pkt 10 Pkt 37 Pcnt 18 C
1780539746 14.33 Volt 260 Pkt 10 Pkt 37 Pcnt 17.5 C
1780539446 14.33 Volt 260 Pkt 10 Pkt 37 Pcnt 17.5 C
1780539146 14.33 Volt 260 Pkt 20 Pkt 38 Pcnt 17.5 C
1780538846 14.33 Volt 260 Pkt 20 Pkt 37 Pcnt 17 C
1780538546 14.33 Volt 260 Pkt 20 Pkt 37 Pcnt 17 C
1780538246 14.33 Volt 270 Pkt 20 Pkt 37 Pcnt 16.5 C
1780537946 14.33 Volt 260 Pkt 20 Pkt 37 Pcnt 16.5 C
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0, 0.5, -64

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)