Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object SQ8MAE-5. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx10m* Rx1h* Eff1h* Eff*
1772749644 14.1 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772749043 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772748443 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772747842 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772747241 14.1 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772746641 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772745440 14.1 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772744839 14.1 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772744239 14.1 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772743638 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772743038 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772742437 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772741836 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772741236 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772740635 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772740035 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772738834 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772738233 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772737032 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772736431 14.1 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772735831 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772735230 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772734630 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772734029 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
1772733428 14.03 Volt 0 Pkt 0 Pkt 100 Pcnt 100 Pcnt
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx10m: 0, 1, 0
Rx1h: 0, 10, 0
Eff1h: 0, 1, 0
Eff: 0, 1, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)