Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object ED1ZBA-3. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dg1h* Eff1h* A5*
1761521520 13.54 Volt 410 Pkt 160 Pkt 68 Pcnt 0 None
1761520619 13.54 Volt 410 Pkt 170 Pkt 72 Pcnt 0 None
1761519719 13.54 Volt 410 Pkt 160 Pkt 71 Pcnt 0 None
1761518820 13.54 Volt 370 Pkt 130 Pkt 68 Pcnt 0 None
1761518819 13.54 Volt 370 Pkt 130 Pkt 68 Pcnt 0 None
1761517919 13.54 Volt 300 Pkt 90 Pkt 63 Pcnt 0 None
1761517020 13.54 Volt 260 Pkt 70 Pkt 56 Pcnt 0 None
1761516121 13.54 Volt 270 Pkt 70 Pkt 56 Pcnt 0 None
1761515220 13.54 Volt 290 Pkt 90 Pkt 60 Pcnt 0 None
1761515219 13.54 Volt 290 Pkt 90 Pkt 60 Pcnt 0 None
1761514320 13.54 Volt 320 Pkt 110 Pkt 63 Pcnt 0 None
1761513420 13.54 Volt 310 Pkt 120 Pkt 69 Pcnt 0 None
1761512520 13.54 Volt 290 Pkt 110 Pkt 71 Pcnt 0 None
1761511620 13.54 Volt 260 Pkt 90 Pkt 70 Pcnt 0 None
1761511619 13.54 Volt 260 Pkt 90 Pkt 70 Pcnt 0 None
1761510720 13.54 Volt 230 Pkt 70 Pkt 66 Pcnt 0 None
1761509820 13.54 Volt 220 Pkt 50 Pkt 59 Pcnt 0 None
1761508920 13.54 Volt 210 Pkt 50 Pkt 56 Pcnt 0 None
1761508021 13.54 Volt 230 Pkt 50 Pkt 56 Pcnt 0 None
1761508019 13.54 Volt 230 Pkt 50 Pkt 56 Pcnt 0 None
1761507120 13.54 Volt 230 Pkt 60 Pkt 59 Pcnt 0 None
1761506220 13.54 Volt 230 Pkt 70 Pkt 60 Pcnt 0 None
1761505320 13.54 Volt 220 Pkt 60 Pkt 59 Pcnt 0 None
1761504420 13.54 Volt 200 Pkt 60 Pkt 63 Pcnt 0 None
1761504419 13.54 Volt 200 Pkt 60 Pkt 63 Pcnt 0 None
*Used Equation Coefficients:
Vin: 0, 0.074, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
A5: 0, 0, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)