Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object LZ0DAP-13. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin:* Rx1h* Dg1h* EffTo* Temp*
1765842046 14.32 Volt 160 Pkt 0 Pkt 88 Pcnt 24.7 C
1765841446 14.32 Volt 170 Pkt 0 Pkt 88 Pcnt 24.84 C
1765840846 14.32 Volt 170 Pkt 0 Pkt 88 Pcnt 24.7 C
1765840246 14.32 Volt 170 Pkt 0 Pkt 88 Pcnt 24.7 C
1765839646 14.32 Volt 170 Pkt 0 Pkt 88 Pcnt 24.84 C
1765839046 14.32 Volt 170 Pkt 0 Pkt 88 Pcnt 24.7 C
1765838457 14.32 Volt 190 Pkt 0 Pkt 88 Pcnt 24.84 C
1765837847 14.32 Volt 190 Pkt 0 Pkt 88 Pcnt 24.84 C
1765837247 14.32 Volt 200 Pkt 0 Pkt 88 Pcnt 24.84 C
1765836647 14.32 Volt 200 Pkt 0 Pkt 88 Pcnt 24.84 C
1765836047 14.32 Volt 200 Pkt 0 Pkt 88 Pcnt 24.84 C
1765835447 14.32 Volt 200 Pkt 0 Pkt 88 Pcnt 24.84 C
1765834847 14.32 Volt 180 Pkt 0 Pkt 88 Pcnt 24.84 C
1765834247 14.32 Volt 180 Pkt 0 Pkt 88 Pcnt 24.84 C
1765833667 14.32 Volt 170 Pkt 0 Pkt 88 Pcnt 24.99 C
1765833047 14.32 Volt 170 Pkt 0 Pkt 88 Pcnt 24.99 C
1765831847 14.32 Volt 150 Pkt 0 Pkt 88 Pcnt 25.14 C
1765831247 14.32 Volt 160 Pkt 0 Pkt 88 Pcnt 24.84 C
1765830047 14.32 Volt 170 Pkt 0 Pkt 88 Pcnt 24.84 C
1765829447 14.32 Volt 170 Pkt 0 Pkt 88 Pcnt 24.84 C
1765828847 14.32 Volt 180 Pkt 0 Pkt 88 Pcnt 24.99 C
1765828247 14.32 Volt 180 Pkt 0 Pkt 88 Pcnt 24.99 C
1765827647 14.32 Volt 180 Pkt 0 Pkt 88 Pcnt 24.99 C
1765827047 14.32 Volt 180 Pkt 0 Pkt 88 Pcnt 24.99 C
1765826447 14.32 Volt 170 Pkt 0 Pkt 88 Pcnt 25.14 C
*Used Equation Coefficients:
Vin:: 0, 0.077, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
EffTo: 0, 1, 0
Temp: 0, 0.147, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)