Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object DB0IS. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time BATT* CPU* CASE* OUT* PA*
1765566373 24.2 V 57.4 C 27 C 17.8 C 0 W
1765565772 23.8 V 57.9 C 26.5 C 17.8 C 4.8 W
1765565171 24.1 V 56.9 C 26 C 17.8 C 0 W
1765564570 24.1 V 57.9 C 27 C 17.8 C 0 W
1765563969 24.1 V 56.9 C 25.5 C 17.8 C 0 W
1765563369 24.1 V 57.4 C 25.5 C 17.8 C 0 W
1765562768 24.1 V 56.9 C 26 C 17.8 C 0 W
1765562168 24.2 V 56.9 C 25.5 C 17.9 C 0 W
1765561567 24.1 V 56.9 C 25.5 C 17.9 C 0 W
1765560991 24.1 V 56.9 C 25.5 C 17.9 C 0 W
1765560366 24.2 V 56.9 C 26 C 17.9 C 0 W
1765559765 24.2 V 57.9 C 26.5 C 17.8 C 0 W
1765558563 24.1 V 57.4 C 26.5 C 17.8 C 0 W
1765557963 24.1 V 57.9 C 26 C 17.8 C 0 W
1765557361 24.2 V 57.4 C 25.5 C 17.8 C 0 W
1765556761 24.1 V 56.9 C 26 C 17.8 C 0 W
1765556179 24.2 V 57.9 C 27 C 17.8 C 0 W
1765555560 24.2 V 57.9 C 27.5 C 17.8 C 0 W
1765554959 24.1 V 56.3 C 25 C 17.9 C 0 W
1765554359 24.2 V 56.9 C 25 C 17.9 C 0 W
1765553758 24.2 V 56.9 C 25.5 C 18 C 0 W
1765553157 24.1 V 56.9 C 25.5 C 17.9 C 0 W
1765552556 24.1 V 56.9 C 26 C 17.8 C 0 W
1765551956 24.2 V 56.9 C 25.5 C 17.8 C 0 W
1765551356 24.1 V 56.9 C 25 C 17.8 C 0 W
*Used Equation Coefficients:
BATT: 0, 0.1, 0
CPU: 0, 0.1, 0
CASE: 0, 0.1, 0
OUT: 0, 0.1, 0
PA: 0, 0.1, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)