Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object OE9XKV-10. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time Vin* Rx1h* Dg1h* Eff1h* RTemp*
1781860294 13.58 Volt 990 Pkt 0 Pkt 75 Pcnt 41 °c
1781859995 13.58 Volt 970 Pkt 0 Pkt 75 Pcnt 40.5 °c
1781859994 13.58 Volt 970 Pkt 0 Pkt 75 Pcnt 40.5 °c
1781859694 13.58 Volt 960 Pkt 0 Pkt 75 Pcnt 40.5 °c
1781859394 13.58 Volt 930 Pkt 0 Pkt 75 Pcnt 40.5 °c
1781859095 13.58 Volt 890 Pkt 0 Pkt 74 Pcnt 40.5 °c
1781859094 13.58 Volt 890 Pkt 0 Pkt 74 Pcnt 40.5 °c
1781855255 13.58 Volt 890 Pkt 0 Pkt 73 Pcnt 40 °c
1781854955 13.58 Volt 900 Pkt 0 Pkt 73 Pcnt 40 °c
1781854655 13.58 Volt 900 Pkt 0 Pkt 74 Pcnt 40 °c
1781854655 13.58 Volt 900 Pkt 0 Pkt 74 Pcnt 40 °c
1781854355 13.58 Volt 890 Pkt 0 Pkt 74 Pcnt 40 °c
1781854055 13.58 Volt 900 Pkt 0 Pkt 74 Pcnt 39.5 °c
1781853779 13.58 Volt 900 Pkt 0 Pkt 75 Pcnt 39.5 °c
1781853779 13.58 Volt 900 Pkt 0 Pkt 75 Pcnt 39.5 °c
1781853455 13.58 Volt 890 Pkt 0 Pkt 75 Pcnt 39.5 °c
1781853155 13.58 Volt 880 Pkt 0 Pkt 76 Pcnt 39.5 °c
1781852855 13.58 Volt 860 Pkt 0 Pkt 76 Pcnt 39.5 °c
1781852855 13.58 Volt 860 Pkt 0 Pkt 76 Pcnt 39.5 °c
1781852555 13.58 Volt 870 Pkt 0 Pkt 77 Pcnt 39.5 °c
1781852255 13.58 Volt 890 Pkt 0 Pkt 76 Pcnt 39.5 °c
1781851955 13.58 Volt 900 Pkt 0 Pkt 77 Pcnt 39.5 °c
1781851955 13.58 Volt 900 Pkt 0 Pkt 77 Pcnt 39.5 °c
1781851655 13.58 Volt 910 Pkt 0 Pkt 78 Pcnt 39 °c
1781851355 13.58 Volt 900 Pkt 0 Pkt 77 Pcnt 39 °c
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
RTemp: 0, 0.5, -64

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)