Time Vin* Rx1h* Dg1h* Eff1h* Temp*
1784694723 13.5 Volt 50 Pkt 10 Pkt 66 Pcnt 12.66 C
1784694423 13.5 Volt 50 Pkt 0 Pkt 67 Pcnt 12.66 C
1784694123 13.5 Volt 50 Pkt 0 Pkt 67 Pcnt 12.66 C
1784693829 13.5 Volt 50 Pkt 0 Pkt 70 Pcnt 12.66 C
1784693523 13.5 Volt 50 Pkt 0 Pkt 68 Pcnt 13.13 C
1784693223 13.5 Volt 50 Pkt 0 Pkt 71 Pcnt 13.13 C
1784692923 13.5 Volt 50 Pkt 0 Pkt 71 Pcnt 13.13 C
1784692623 13.5 Volt 60 Pkt 0 Pkt 74 Pcnt 13.13 C
1784692323 13.5 Volt 60 Pkt 0 Pkt 73 Pcnt 13.13 C
1784692023 13.5 Volt 60 Pkt 0 Pkt 71 Pcnt 13.61 C
1784691723 13.5 Volt 60 Pkt 0 Pkt 71 Pcnt 13.13 C
1784691423 13.5 Volt 60 Pkt 0 Pkt 69 Pcnt 13.61 C
1784691123 13.5 Volt 60 Pkt 10 Pkt 69 Pcnt 13.61 C
1784690823 13.5 Volt 60 Pkt 10 Pkt 69 Pcnt 13.61 C
1784690523 13.5 Volt 60 Pkt 10 Pkt 65 Pcnt 13.61 C
1784690223 13.5 Volt 60 Pkt 10 Pkt 64 Pcnt 13.61 C
1784689923 13.5 Volt 60 Pkt 10 Pkt 64 Pcnt 14.09 C
1784689623 13.5 Volt 60 Pkt 10 Pkt 65 Pcnt 14.09 C
1784689323 13.5 Volt 70 Pkt 10 Pkt 66 Pcnt 14.09 C
1784689023 13.5 Volt 90 Pkt 10 Pkt 66 Pcnt 14.09 C
1784688723 13.5 Volt 100 Pkt 10 Pkt 68 Pcnt 14.09 C
1784688423 13.5 Volt 110 Pkt 10 Pkt 71 Pcnt 14.56 C
1784688123 13.5 Volt 110 Pkt 10 Pkt 69 Pcnt 14.56 C
1784687823 13.5 Volt 100 Pkt 10 Pkt 70 Pcnt 14.56 C
1784687523 13.5 Volt 100 Pkt 0 Pkt 68 Pcnt 15.04 C
*Used Equation Coefficients:
Vin: 0, 0.075, 0
Rx1h: 0, 10, 0
Dg1h: 0, 10, 0
Eff1h: 0, 1, 0
Temp: 0.0005247, 0.3137172, -47.6223

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)