Overview Statistics Trail Chart Weather Telemetry Raw packets
 

This is the latest recevied telemetry packets stored in our database for station/object E21TMW-1. If no packets are shown the sender has not sent any telemetry packets the latest 10 day(s).

Telemetry packets is used to share measurements like repeteater parameters, battery voltage, radiation readings (or any other measurements).

<< 1 2 3 4 >>
Time RxTraffic* TxTraffic* RxDrop* WiFi* BaudRate*
1772913120 0 Pkt 0 Pkt 0 Pkt 53 dB 19200 bps
1772912520 2 Pkt 1 Pkt 0 Pkt 53 dB 19200 bps
1772911920 2 Pkt 1 Pkt 1 Pkt 54 dB 19200 bps
1772911320 1 Pkt 0 Pkt 0 Pkt 53 dB 19200 bps
1772910720 2 Pkt 1 Pkt 0 Pkt 54 dB 19200 bps
1772910120 2 Pkt 1 Pkt 1 Pkt 53 dB 19200 bps
1772909520 1 Pkt 0 Pkt 0 Pkt 54 dB 19200 bps
1772908920 2 Pkt 1 Pkt 1 Pkt 53 dB 19200 bps
1772908320 1 Pkt 0 Pkt 0 Pkt 54 dB 19200 bps
1772907720 1 Pkt 0 Pkt 0 Pkt 53 dB 19200 bps
1772907120 2 Pkt 1 Pkt 1 Pkt 54 dB 19200 bps
1772906520 2 Pkt 0 Pkt 0 Pkt 53 dB 19200 bps
1772905920 1 Pkt 0 Pkt 0 Pkt 54 dB 19200 bps
1772905321 1 Pkt 1 Pkt 1 Pkt 54 dB 19200 bps
1772904720 2 Pkt 1 Pkt 1 Pkt 54 dB 19200 bps
1772904120 0 Pkt 0 Pkt 0 Pkt 54 dB 19200 bps
1772903520 2 Pkt 1 Pkt 1 Pkt 54 dB 19200 bps
1772902920 1 Pkt 1 Pkt 1 Pkt 54 dB 19200 bps
1772902320 1 Pkt 0 Pkt 0 Pkt 54 dB 19200 bps
1772901720 1 Pkt 1 Pkt 0 Pkt 54 dB 19200 bps
1772901120 2 Pkt 1 Pkt 0 Pkt 54 dB 19200 bps
1772900520 1 Pkt 0 Pkt 0 Pkt 53 dB 19200 bps
1772899920 1 Pkt 1 Pkt 1 Pkt 54 dB 19200 bps
1772899320 2 Pkt 1 Pkt 1 Pkt 55 dB 19200 bps
1772898720 1 Pkt 0 Pkt 0 Pkt 55 dB 19200 bps
*Used Equation Coefficients:
RxTraffic: 0, 1, 0
TxTraffic: 0, 1, 0
RxDrop: 0, 1, 0
WiFi: 0, 1, 100
BaudRate: 0, 1, 0

  • The parameter names for the analog channels will be Value1, Value2, Value3 (up to Value5) if station has not sent a PARAM-packet that specifies the parameter names for each analog channel.
  • Each analog value is a decimal number between 000 and 255 (according to APRS specifications). The receiver use the telemetry equation coefficientsto to restore the original sensor values. If no EQNS-packet with equation coefficients is sent we will show the values as is (this corresponds to the equation coefficients a=0, b=1 and c=0).
    The sent equation coefficients is used in the equation: a * value2 + b * value + c.
  • The units for the analog values will not be shown if station has not sent a UNIT-packet specifying what unit's to use.
  • The parameter names for the digital bits will be Bit1, Bit2, Bit3 (up to Bit8) if station has not sent a PARAM-packet that specifies the parameter names for each digital bit.
  • All bit labels will be named "On" if station has not sent a UNIT-packet that specifies the label of each bit.
  • A bit is considered to be On when the bit is 1 if station has not sent a BITS-packet that specifies another "Bit sense" (a BITS-packet specify the state of the bits that match the BIT labels)